ioppulse.blogg.se

Configuring hp smart array controller
Configuring hp smart array controller










configuring hp smart array controller
  1. #Configuring hp smart array controller install#
  2. #Configuring hp smart array controller Offline#
  3. #Configuring hp smart array controller download#

HP assumes you are qualified in the servicing of computer equipment. It exists in three interface formats: the HP SSA GUI, the HP SSA CLI, and HP SSA Scripting. HP Smart Array Controllers for HP ProLiant Servers User Guide Abstract This document includes feature, installation, and configuration information about HP Smart Array Controllers and is for the person who installs, administers, and troubleshoots servers and storage systems.

configuring hp smart array controller

Keep this HP Smart Array controller users guide handy. HP SSA is the main tool for configuring arrays on HP Smart Array controllers. The tools used for managing and configuring storage are the same in all of those environments. The windows version can be downloaded Here. Note: The ACU has been superceeded by the HPE Smart Storage Administrator.

#Configuring hp smart array controller Offline#

The Offline utilty can be downloaded here. The latest HP Proliant Array configuration utility (ACU) can be downloaded from HPs Enterprise website. We provide administrators with tools for Smart Array configuration, storage management, and diagnostics. HP engineers continue to enhance Smart Array performance, expansion, migration, and data availability capabilities. This document includes feature, installation, and configuration information about Hewlett Packard Enterprise Smart Array SR Gen10 and is for the person who installs, administers, and troubleshoots servers and storage systems.

#Configuring hp smart array controller download#

Let the controller discover the new array. HP is the only server provider with a seamless storage solution set that spans the range from embedded Smart Array controllers in servers to plug-in PCI Smart Array controllers to SAN-attached Modular Smart Arrays storage. Where can I download the HP RAID array configuration utility. Our Smart Array controllers support RAID levels 0, 1, 1+0, 5, 6, 50, and 60. Then boot with your old drives and see if they're detected. Go into the BIOS or DL180 setup disk Array Config and delete the RAID 1+0 array.

#Configuring hp smart array controller install#

i need to make my controller detectable inorder to install more hard disks and configure raid 5. When you brought up the system with your old drives, you should have again deleted the new data logical drive either in the BIOS raid utility or with the Smartstart/DL180 Setup Array Configuration utility and let the controller detect the array/logical drive. i do have a smart array controller e200i, i know that because during the POST(startup) it displays initializing smart array controller e200i and it finds my 2 logical drives.

configuring hp smart array controller

When you went to step #3 in the first drive replacement process Boot up the server and acknowledge errors about failed drives, did you DELETE the removed array/logical drive or just mark it as failed? That's probably the source of the problem here. The removed drives still have the RAID metadata on them.












Configuring hp smart array controller